This board works on the principle of adjacent equalization, so it can't be used as a maintenance tool. To connect the battery, it should be used together with the carp electric protection board. The pressure difference generated by charging and discharging triggers the equalization board to work to realize energy transfer equalization. Inductive energy transfer balance board, high current 1.2A energy transfer battery voltage balancer, significantly balance the battery voltage, and improve the overall use efficiency of the battery pack!


The working voltage is 2.0V-4.5V, which is common for ternary iron batteries, but not for LTO acid batteries.


1. When the balance light is on, the balance work is started.


2. The equalizing lamp goes out and the equalizing circuit goes to sleep.


3. The balance light flashes, the string is disconnected, or the circuit is faulty.


Adjacent pressure difference is above 0.1V (current is around 0.5-0.7A).


Adjacent differential pressure is above 0.2V (reaching the maximum equilibrium current of 1.2A).


The smaller the pressure difference, the smaller the equilibrium current.